Mã lỗi E020-0430 — Canon iR Advance C9280 Pro

Code: E020-0430

Description: Upper limit error for output of Toner Density Sensor (Bk) at initial installation. When executing the initial installation mode of the Developing Assembly (COPIER > FUNCTION > INSTALL > INISET-K), output failed to reach 128 although the control voltage value of the Toner Density Sensor reached 55 or smaller.
Remedy: 1. Check the connection between the toner density sensor and the DC controller PCB. (Connector, Breaking (Breaking (shorting))) <Y> sensor side: J7133, J8028, J8087 PCB side: J1244, J8085 <M> sensor side: J7134, J8029, J8088 PCB side: J1244, J8085 <C> sensor side: J7135, J8030, J8089 PCB side: J1244, J8086 <Bk> sensor side: J7146, J8015, J8117 PCB side: J1244, J8080 2. Check whether disconnection or Breaking (Breaking (shorting)) of the toner density sensor occurs or not. 3. Replace the developing assembly