Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR Advance C9280 Pro

Code: E000-0001

Description: Fixing Film temperature rise is insufficient at power ON.Fixing main thermistor (THM1-1) temperature does not reach 50 degrees Celsius within 20 seconds after startup of fixing film temperature control.
Remedy: Check if the detection temperature of the thermistor is risen in service mode (COPIER> DISPLAY> ANALOG> FIX-xx). A. In case that either one of the thermistor detection temperature is risen A-1. Replace the fixing film unit A-2. Faulty drawer connector -> Clean the drawer connector or replace the fixing drawer cable B. In case that neither of them are not risen B-1. Check the connection of the fixing thermistor (to see if the connection of the drawer is faulty, the connector is physically removed or disconnected) -> replace the fixing film unit B-2. Check the connection of the IH power connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-3. Replace the IH power unit B-4. Replace the DC controller PCB NOTE: After performing the above remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR

Code: E001-0001

Description: Abnormal temperature rise of fixing main thermistor. Fixing main thermistor (THM1) sensed an abnormal high temperature. (ASIC detection)
Remedy: Check the detection temperature of the fixing main thermistor (THM1) in service mode (COPIER> DISPLAY> ANALOG> FIX-UC). A. In case that the detection temperature is 250 degC A-1. The cable of the fixing main thermistor is caught -> replace the fixing film unit B. In case that the detection temperature is other than 250 degC B-1. Replace the DC controller PCB NOTE: After performing the above remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR

Code: E001-0002

Description: Abnormal temperature rise of fixing subthermistor 1 (THM3). Fixing subthermistor 1 (THM3) sensed an abnormal high temperature. (ASIC detection)
Remedy: Check the detection temperature of the fixing sub thermistor 1 (THM3) in service mode (COPIER> DISPLAY> ANALOG> FIX-UE). A. In case that the detection temperature is 250 degC A-1. The cable of the fixing sub thermistor 1 is caught -> replace the fixing film unit B. In case that the detection temperature is other than 250 degC B-1. Location of the fixing main thermistor is inappropriate -> replace the fixing film unit B-2. Replace the DC controller PCB NOTE: After performing the above remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR

Code: E001-0003

Description: Abnormal temperature rise of fixing subthermistor 2 (THM4). Fixing subthermistor 2 (THM4) sensed an abnormal high temperature. (ASIC detection)
Remedy: Check the detection temperature of the fixing sub thermistor 2 (THM4) in service mode (COPIER> DISPLAY> ANALOG> FIX-UE2). A. In case that the detection temperature is 250 degC A-1. The cable of the fixing sub thermistor 2 is caught ->replace the fixing film unit B. In case that the detection temperature is other than 250 degC B-1. Location of the fixing main thermistor is inappropriate -> replace the fixing film unit B-2. Replace the DC controller PCB NOTE: After performing the above remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR

Code: E001-0011

Description: Fixing main thermistor abnormal temperature rise. Fixing main thermistor (THM1) detected abnormal high temperature. (software detection)
Remedy: Check the detection temperature of the fixing main thermistor (THM1) in service mode (COPIER> DISPLAY> ANALOG> FIX-UC). A. In case that the detection temperature is 250 degC A-1. The cable of the fixing main thermistor is caught -> replace the fixing film unit B. In case that the detection temperature is other than 250 degC B-1. Replace the DC controller PCB NOTE: After performing the above remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR

Code: E001-0012

Description: Fixing sub thermistor 1 (THM3) abnormal temperature rise. Fixing sub thermistor 1 (THM3) detected abnormal high temperature. (software detection)
Remedy: Check the detection temperature of the fixing sub thermistor 1 (THM3) in service mode (COPIER> DISPLAY> ANALOG> FIX-UE). A. In case that the detection temperature is 250 degC A-1. The cable of the fixing sub thermistor 1 is caught -> replace the fixing film unit B. In case that the detection temperature is other than 250 degC B-1. Location of the fixing main thermistor is inappropriate -> replace the fixing film unit B-2. Replace the DC controller PCB NOTE: After performing the above remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR

Code: E001-0013

Description: Fixing sub thermistor 2 (THM4) abnormal temperature rise. Fixing sub thermistor 2 (THM4) detected abnormal high temperature. (software detection)
Remedy: Check the detection temperature of the fixing sub thermistor 2 (THM4) in service mode (COPIER> DISPLAY> ANALOG> FIX-UE2). A. In case that the detection temperature is 250 degC A-1. The cable of the fixing sub thermistor 2 is caught -> replace the fixing film unit B. In case that the detection temperature is other than 250 degC B-1. Location of the fixing main thermistor is inappropriate -> replace the fixing film unit B-2. Replace the DC controller PCB NOTE: After performing the above remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR

Code: E001-0014

Description: Abnormal temperature rise of Fixing Edge Rear Thermistor (THM5). The Fixing Edge Rear Thermistor (THM5) detected abnormal high temperature (software detection).
Remedy: Check the detected temperature of the Fixing Edge Rear Thermistor (THM5) in service mode (COPIER > DISPLAY > ANALOG > FIX-UE). A. When the detected temperature was 260 deg C or higher A-1. Cable of the Fixing Edge Rear Thermistor is caught. -> Replace the Fixing Film Unit. B. When the detected temperature was lower than 260 deg C B-1. The Fixing Main Thermistor is not securely attached. -> Replace the Fixing Film Unit. B-2. Replace the DC Controller PCB. NOTE: After performing the remedy work above, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie