Code: E003-0
Description: Fixing low temperature
Causes: The reading of the main thermistor fails to exceed 40 deg C within 4 sec after the start of the heater during the wait period. While heater temperature control is under way during initial rotation, the reading of the main thermistor is 70 deg C or lower continuously for 4 sec or more. While heater temperature control is under way during a standby state, the reading of the main thermistor is 50 deg C or less continuously for 0.5 or more. While heater temperature control is under way during printing, the reading of the main thermistor is 80 deg C or less continuously for 0.5 sec or more. While heater temperature control is under way during printing, the reading of the main thermistor is 40 deg C or lower than the target temperature continuously for 0.5 sec or more. The reading of any of the sub thermistors (1, 2, 3) fails to exceed 60 deg C or more within 4 sec after the start of the heater during the wait period. Cause The main thermistor is faulty. The DC controller PCB is faulty. The connector has
Remedy: - Replace the fixing film unit. - Replace the DC controller PCB.