Causes: When heater temperature control is under way during initial rotation, the reading of the main thermistor fails to reach the target temperature within 80 sec. Cause The fixing film unit is faulty. The DC controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the DC controller PCB.
Causes: When the heater is on, the heater drive current level is below a specific value for as long as 5 waves of the zero-cross signal. Cause The fixing film unit is faulty. The DC controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the DC controller PCB.
Causes: The reading of the main thermistor is 240 deg C or more continuously for 0.1 sec or more. Cause The main thermistor is faulty. The DC controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the DC controller PCB.
Causes: The reading of the sub thermistor is 300 deg C or more continuously for 0.5 sec or more. Cause The sub thermistor is faulty. The DC controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the DC controller PCB.
Causes: The reading of the main thermistor fails to exceed 40 deg C within 4 sec after the start of the heater during the wait period. While heater temperature control is under way during initial rotation, the reading of the main thermistor is 70 deg C or lower continuously for 4 sec or more. While heater temperature control is under way during a standby state, the reading of the main thermistor is 50 deg C or less continuously for 0.5 or more. While heater temperature control is under way during printing, the reading of the main thermistor is 80 deg C or less continuously for 0.5 sec or more. While heater temperature control is under way during printing, the reading of the main thermistor is 40 deg C or lower than the target temperature continuously for 0.5 sec or more. The reading of any of the sub thermistors (1, 2, 3) fails to exceed 60 deg C or more within 4 sec after the start of the heater during the wait period. Cause The main thermistor is faulty. The DC controller PCB is faulty. The connector has
Remedy: - Replace the fixing film unit. - Replace the DC controller PCB.
Causes: The reading of any of the sub thermistors (1, 2, 3) fails to exceed 60 deg C within 4 sec after the start of the heater during the wait period. Cause The sub thermistor is faulty. The DC controller PCB is faulty. The connector has poor contact, or the harness is faulty.
Remedy: - Replace the fixing film unit. - Replace the DC controller PCB.
Causes: The main motor fails to reach its normal rotation speed within 1.2 sec after it has started. Cause The main motor is faulty. The DC controller PCB is faulty.
Remedy: - Replace the main motor. - Replace the DC controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.