Code: E003-0000
Description: Abnormally low temperature in fixing unit
Causes: The detected temperature of the main thermistor is 100 deg C (equivalent to approx. 2.60V) or lower for 0.5 sec. or longer. Cause: Low voltage power supply circuit board defect, main thermistor broken wire, DC controller PCB defect
Remedy: - Check the connector of the low-voltage power supply PCB. - Replace the fixing film unit. - Replace the DC controller PCB.