Causes: The detected temperature of the main thermistor does not rise above 5 deg C (temperature at power ON is 0 deg C) within one second of the heater being energised. Cause: Main thermistor broken wire, fixer heater broken wire, DC controller PCB defect
Remedy: - Check the connector of the low-voltage power supply PCB. - Replace the fixing film unit. - Replace the DC controller PCB.
Description: Abnormally high temperature in fixing unit
Causes: The detected temperature of the main thermistor is 225 deg C (equivalent to approx. 0.84V) or higher for 0.5 sec. or longer. Cause: Main thermistor defect, DC controller PCB defect
Remedy: - Check the connector of the low-voltage power supply PCB. - Replace the fixing film unit. - Replace the DC controller PCB.
Description: Abnormally high temperature in fixing unit
Causes: The detected temperature of the main thermistor is 245 deg C (equivalent to approx. 2.12V) or higher for 0.5 sec. or longer. Cause: Main thermistor defect, DC controller PCB defect
Remedy: - Check the connector of the low-voltage power supply PCB. - Replace the fixing film unit. - Replace the DC controller PCB.
Description: Abnormally low temperature in fixing unit
Causes: The detected temperature of the main thermistor is 100 deg C (equivalent to approx. 2.60V) or lower for 0.5 sec. or longer. Cause: Low voltage power supply circuit board defect, main thermistor broken wire, DC controller PCB defect
Remedy: - Check the connector of the low-voltage power supply PCB. - Replace the fixing film unit. - Replace the DC controller PCB.
Description: Abnormally low temperature in fixing unit
Causes: The detected temperature of the sub-thermistor fails to reach 100 °C (equivalent to approx. 0.38V) within 0.5 sec. or longer of the heater being energised. Cause:Sub-thermistor defect, DC controller circuit board defect
Remedy: - Check the connector of the low-voltage power supply PCB. - Replace the fixing film unit. - Replace the DC controller PCB.
Causes: ETB motor speed detection signal frequency does not reach specified frequency within 3.5 sec. or longer of the ETB motor drive starting. Cause: ETB motor defect, DC controller PCB defect
Remedy: - Replace ETB motor - Replace DC controller PCB
Causes: ETB motor speed detection signal frequency reaches the specified frequency but is then out of synch after 2 sec. or longer of operation. Cause: ETB motor defect, DC controller PCB defect
Remedy: - Replace ETB motor - Replace DC controller PCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.