Code: E015-0000
Description: Developing disengagement motor failure
Causes: Developing disengagement motor failure The standard flag was not detected even when driving was performed for 1000ms after rotation of the motor. The standard flag was not detected even when driving was performed for 8000ms at the time of switching from the full-color position to "all disengagement". The standard flag was not detected even when driving was performed for 3000ms at the time of switching from the monochrome position to "all disengagement".
Remedy: Reconnect the connector J518 of the developing disengagement motor, the connector J1005 on the driver PCB, and the connector J91 on the DC controller PCB. Check the condition of the developing disengagement sensor in the sensor monitor mode. If a failure is found, replace the developing disengagement sensor assembly. Execute the developing assembly engagement/disengagement drive test in the actuator drive mode. If the developing assembly does not perform engagement/disengagement, replace the developing disengagement motor.