Code: 922
Description: Fuser Error Fuser failed to reach standby temperature.
Remedy: Lamp cable LVPS/HVPS Fuser Unplug the MFP and disconnect the fuser lamp cable plug from the LVPS/HVPS board connector CN102. Check for continuity across the fuser lamp by checking across the connector pins. • If there is continuity, go to Step 1: Continuity. • If there is no continuity, go to Step 2: No continuity. Step 1: Continuity Turn the MFP on with only the fuser power disconnected. Measure the voltage at connector CN102 on the LVPS/HVPS. It should match the line voltage. If line voltage is not present, see “LVPS/HVPS service check” for more information. Make sure the fuser thermistor is correctly connected to the controller board. If the problem persists, disconnect the thermistor cable at J15 and check for less than +5 V dc on pin 1. Pin 2 should be ground. If line voltage is incorrect on pin 1, see “Controller card service check” for more information. Step 2: No continuity Check the lamp cable for continuity. • If correct, replace the fuser. • If incorrect, replace the lamp cable. Disconnect the thermistor cable from J15 on the controller card. Measure the resistance across the ends of the thermistor cable. See “Controller card” for more information. Replace the fuser assembly if the resistance is lower than 1K ohm or shorted. Note: Resistance measures approximately 240K ohms when cool and 1.4K ohms hot.