Code: 200.06
Description: Imaged page not expected page. Bouncy pass thru sensor.
Remedy: This test is used to determine if the input tray sensors are working correctly. To run the Input Tray Sensor Test: 1. Touch to select the Sensor Test from INPUT TRAY TESTS. 2. Touch to select the input source from the sources displayed on the Sensor Test menu. All installed sources are listed. 3. Select the sensor to test. Various sources have different combinations of sensors. [sensor selected]=Open displays. • Empty—Input tray empty sensor • Low—Input tray paper low sensor • passThru—Input tray pass thru sensor 4. Once this message displays, the servicer can manually actuate each sensor. The tray empty sensor can be actuated by hand, however a sheet of paper can be used to cover the pass thru sensor. When the sensor is closed, Closed displays; when the sensor is open, Open displays. 5. Press Stop ( ) to exit the test.