Description: POST Error Output bin cable not connected.
Remedy: 1 1. Turn the printer off. 2. Remove the rear frame cover. See “Rear frame cover removal”. 3. Reseat the bin full sensor cable in connector JBIN1. Did the error clear? Problem resolved. Go to step 2. 2 Check the bin full sensor cable in connector JBIN1 for pinch points and any other damage to the cable or connector. Is the cable damaged? Replace the bin full sensor with cable. See “Bin full sensor assembly removal”. Go to step 3. 3 1. Disconnect the cable in JBIN1 connector. 2. Connect the new bin full sensor flag connector in the JBIN1 connector. 3. Enter Diagnostics mode (press and hold buttons 3 and 6, turn on the MFP, and release the buttons when the progress bar displays. 4. Touch SENSOR TESTS. 5. Touch Dynamic Sensors. 6. Touch Other Sensors. 7. Touch Bin Full. 8. Activate the new bin full sensor by pressing on the flag, as shown. Did the bin full sensor change from Open to Closed on the touchscreen? Replace the bin full sensor and cable. See “Bin full sensor assembly removal”. Replace the system board. See “System board removal”.