Code: 0420
Description: Paper feeder PF-70*/PF-75 communication problem
• Communication errors from the communication microcomputer on the engine controller PWB. No communication: there is no reply after 3 retries. Abnormal communication: a communication error (parity or checksum error) is detected five times in succession.
• Communication errors from the communication microcomputer on the engine controller PWB. No communication: there is no reply after 3 retries. Abnormal communication: a communication error (parity or checksum error) is detected five times in succession.
Causes: Poor contact in the connector terminals. Defective engine controller PWB. Defective paper feeder main board.
Remedy: Check the connection of connectors CN3 on the engine controller PWB and the connector on the paper feeder main board, and the continuity across the connector terminals. Repair or replace if necessary.Replace the engine controller PWB and check for correct operation.Replace the paper feeder main board and check for correct operation.