Các lỗi thường gặp

Code :
  • Code: 0110
  • Description: Backup memory data problem
    • Data in the specified area of the backup memory does not match the specified values.
  • Causes: Problem with the backup memory data. Defective backup RAM.
  • Remedy: Turn safety switch 1 off and back on .
    If the 0110 is displayed after turn power switch off and back on, replace the backup RAM.
  • Code: 0210
  • Description: Operatior panel PWB communication problem
    • There is no reply after 20 retries at communication.sion.
  • Causes: Poor contact in the connector terminals. Defective engine controller PWB or operatior panel PWB.
  • Remedy: Check the connection of connectors CN21 on the engine controller PWB and CN1 on the operatior panel PWB, and the continuity across the connector terminals. Repair or replace if necessary.Replace the engine controller PWB or operatior panel PWB and check for correct operation.
  • Code: 0420
  • Description: Paper feeder PF-70*/PF-75 communication problem
    • Communication errors from the communication microcomputer on the engine controller PWB. No communication: there is no reply after 3 retries. Abnormal communication: a communication error (parity or checksum error) is detected five times in succession.
  • Causes: Poor contact in the connector terminals. Defective engine controller PWB. Defective paper feeder main board.
  • Remedy: Check the connection of connectors CN3 on the engine controller PWB and the connector on the paper feeder main board, and the continuity across the connector terminals. Repair or replace if necessary.Replace the engine controller PWB and check for correct operation.Replace the paper feeder main board and check for correct operation.
  • Code: 0440
  • Description: Finisher communication problem
    • Communication errors from the communication microcomputer on the engine controller PWB. No communication: there is no reply after 3 retries. Abnormal communication: a communication error (parity or checksum error) is detected five times in succession.
  • Causes: Poor contact in the connector terminals. Defective engine controller PWB. Defective finisher main board.
  • Remedy: Check the connection of connectors CN4, CN5 on the engine controller PWB and CN2 on the finisher main board, and the continuity across the connector terminals. Repair or replace if necessary.Replace the engine controller PWB and check for correct operation.Replace the finisher main board and check for correct operation.
  • Code: 0470
  • Description: Switchback unit communication problem
    • Communication errors from the communication microcomputer on the engine controller PWB. No communication: there is no reply after 3 retries. Abnormal communication: a communication error (parity or checksum error) is detected five times in succession.
  • Causes: Poor contact in the connector terminals. Defective engine controller PWB. Defective switchback unit main board.
  • Remedy: Check the connection of connectors CN3 on the engine controller PWB and the continuity across the connector terminals. Repair or replace if necessary.Replace the engine controller PWB and check for correct operation.Replace the switchback unit main board and check for correct operation.
  • Code: 1010
  • Description: Upper lift motor problem
    • When the upper cassette is inserted, the upper lift limit switch does not turn on within 6 s of the upper lift motor turning on and the upper lift limit switch does not turn on by turning off the upper lift motor for 200 ms and retrying twice. • During printing, the upper lift limit switch does not turn on within 200 ms of the upper lift motor turning on.
  • Causes: Broken gears or couplings of the upper lift motor. Defective upper lift motor. Poor contact of the upper lift motor connector terminals. Defective upper lift limit switch.
  • Remedy: Replace the upper lift motor.Check for continuity across the coil. If none, replace the upper lift motor.Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable.Check if CN13-B9 on the engine controller PWB goes low when the upper lift limit switch is turned off. If not, replace the upper lift limit switch.Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable.
  • Code: 1020
  • Description: Lower lift motor problem
    • When the lower cassette is inserted, the lower lift limit switch does not turn on within 6 s of the lower lift motor turning on and the lower lift limit switch does not turn on by turning off the lower lift motor for 200 ms and retrying twice. • During printing, the lower lift limit switch does not turn on within 200 ms of the lower lift motor turning on.
  • Causes: Broken gears or couplings of the lower lift motor. Defective lower lift motor. Poor contact of the lower lift motor connector terminals. Defective lower lift limit switch. Poor contact of the lower lift limit switch connector terminals.
  • Remedy: Replace the lower lift motor. Check for continuity across the coil. If none, replace the lower lift motor. Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable. Check if CN13-B15 on the engine controller PWB goes low when the lower lift limit switch is turned off. If not, replace the lower lift limit switch. Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable.
  • Code: 1030
  • Description: Desk upper lift motor problem
    • When the upper cassette of the paper feeder PF-70 is inserted, the desk upper lift limit switch does not turn on within 6 s of the desk upper lift motor turning on and the desk upper lift limit switch does not turn on by turning off the desk upper lift motor for 200 ms and retrying twice. • During printing, the desk upper lift limit switch does not turn on within 200 ms of the desk upper lift motor turning on.
  • Causes: Broken gears or couplings of the desk upper lift motor. Defective desk upper lift motor. Poor contact of the desk upper lift motor connector terminals. Defective desk upper lift limit switch.
  • Remedy: Replace the desk upper lift motor. Check for continuity across the coil. If none, replace the desk upper lift motor. Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable. Check if CN1-5 on the desk main board goes low when the desk upper lift limit switch is turned off. If not, replace the desk upper lift limit switch.