Code: 4010
Description: Polygon motor steady-state problem
• The polygon motor rotation is not stable for 600 ms after the polygon motor rotation has been stabilized.
• The polygon motor rotation is not stable for 600 ms after the polygon motor rotation has been stabilized.
Causes: Poor contact in the polygon motor connector terminals. Defective polygon motor. Defective power supply unit. Defective engine controller PWB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the LSU (see page 1-6-11). Check if 24 V DC is supplied to CN2-1 on the engine controller PWB. If not, replace the power supply unit. Check if 24 V DC is output from CN8-10 on the engine controller PWB. If not, replace the engine controller PWB.