Code: C3200
Description: Exposure lamp problem After the reading starting, when input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s.
Causes: Poor contact in the connector terminals. Defective exposure lamp. Incorrect shading position. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC16 on the engine PWB and the connector on the inverter PWB, and the continuity across the connector terminals. Repair or replace if necessary.
Defective exposure lamp. Replace the exposure lamp.
Incorrect shading position. Adjust the position of the platen (shading plate). If the problem still occurs, replace the scanner home position switch.
Defective PWB. Replace the engine PWB or scanner inverter PWB and check for correct operation.
Defective exposure lamp. Replace the exposure lamp.
Incorrect shading position. Adjust the position of the platen (shading plate). If the problem still occurs, replace the scanner home position switch.
Defective PWB. Replace the engine PWB or scanner inverter PWB and check for correct operation.