Code: C610
Description: Broken fixing unit thermistor wire • The fixing temperature does not increase for 40 s after the fixing heaters have been turned on for warming up. • The fixing temperature remains below 50C/122F for 10 s continuously after the fixing heaters have been turned on during stabilization.
Causes: Poor contact of the fixing unit thermistor connector terminals. Broken fixing unit thermistor wire. Fixing unit thermistor installed incorrectly. Fixing unit thermostat triggered. Fixing unit heater M or S installed incorrectly. Broken fixing unit heater M or S wire.
Remedy: Check the connection of connector CN3-B8 on the engine PCB and the continuity across the connector terminals. Repair or replace if necessary. Measure the resistance. If it is infinite, replace the fixing unit thermistor. Check and reinstall if necessary. Check for continuity. If none, replace the fixing unit thermostat. Check and reinstall if necessary. Check for continuity. If none, replace the fixing unit heater M or S.