Mã lỗi C0098 — Kyocera KMC1530

Code: C0098

Description: Fusing Roller pressure/ retraction failure
• No change is observed in the encoder pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for retraction direction during retraction control. • No change is observed in the encoder pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for pressure direction during pressure control. • The Fusing Pressure Position Sensor is not activated (pressed position) even when 31 motor encoder pulses have been counted after the Fusing Pressure/Retraction Motor has started turning for pressure direction during pressure control.
Remedy: 1 Fusing Pressure/Retraction Motor rotation when the Fusing Roller is retracted: the voltage across PJ14I-4A on Master Board and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. YES: Check motor connector for connection. Change motor. NO: Change Master Board. 2 I/O check for Fusing Pressure Position Sensor when the Fusing Roller is retracted: the voltage across PJ6I-11B on Master Board and GND is DC 0 V when the sensor is unblocked (retracted position) and DC 5 V when the sensor is blocked. YES: Change Master Board. NO: Check sensor installation. Correct detecting plate. Check sensor connector for connection. Change sensor. 3 Fusing Pressure/Retraction Motor rotation when the Fusing Roller is pressed: the voltage across PJ14I-5A on Master Board and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. NO: Change Master Board. 4 I/O check for Fusing Pressure Position Sensor when the Fusing Roller is pressed: the voltage across PJ6I-11B on Master Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (pressed position). YES: Change Master Board. NO: Check sensor installation. Correct detecting plate. Check sensor connector for connection. Change sensor. 5 I/O check for Fusing Retraction Position Sensor operation while the Fusing Pressure/ Retraction Motor is turning: the voltage across PJ17I-3B on Master Board and GND remains DC 0 V when the sensor is unblocked or remains DC 5 V when the sensor is blocked while the motor remains stationary, and alternates between DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked while the motor is turning. YES: Change Master Board. NO: Check sensor installation. Correct detecting plate. Check sensor connector for connection. Change sensor.

← Xem tất cả mã lỗi Kyocera KMC1530

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie