Description: Main Motor’s failure to turn
The Main Motor Lock signal remains faulty for a predetermined continuous period of time while the Main Motor is turning.
Remedy: 1 Main Motor turns when the Start key is pressed. NO: Check connector for connection. Correct drive coupling (drive transmitting gear engagement). 2 Main Motor rotation when the Start key is pressed: the voltage across PJ13I-7A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board. 3 Main Motor rotation when the Start key is pressed: the voltage across PJ7PU1-4 on DC Power Supply 1 and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. NO: Change DC Power Supply 1.
Description: Main Motor turning at abnormal timing
The Main Motor Lock signal remains faulty for a predetermined continuous period of time while the Main Motor remains stationary.
Remedy: 1 Main Motor rotation while it is being energized: the voltage across PJ13I-7A on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.
Description: Imaging Unit Motor C’s failuretoturn
The Lock signal remains faulty for a continuous 1sec. period after the motor rotation has stabilized and before the motor starts decelerating.
Remedy: 1 Imaging Unit Motor turns when the Start key is pressed. NO: Correct drive coupling (drive transmitting gear engagement, coupling engagement). Check that the LED Assy is locked in position. 2 Imaging Unit Motor rotation when the Start key is pressed: Cyan: the voltage across PJ12I-3B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Magenta: the voltage across PJ12I-7A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Yellow: the voltage across PJ12I-3A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Black: the voltage across PJ12I-7B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board.
Description: Imaging Unit Motor C turning at abnormal timing
The Lock signal remains faulty for a continuous 1sec. period after the motor has completely stopped and before the motor starts accelerating.
Remedy: 1 Imaging Unit Motor rotation while it is being energized: Cyan: the voltage across PJ12I-3B on Master Board and GND remains DC 0 V. Magenta: the voltage across PJ12I-7A on Master Board and GND remains DC 0 V. Yellow: the voltage across PJ12I-3A on Master Board and GND remains DC 0 V. Black: the voltage across PJ12I-7B on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.
Description: Imaging Unit Motor M’s failuretoturn
The Lock signal remains faulty for a continuous 1sec. period after the motor rotation has stabilized and before the motor starts decelerating.
Remedy: 1 Imaging Unit Motor turns when the Start key is pressed. NO: Correct drive coupling (drive transmitting gear engagement, coupling engagement). Check that the LED Assy is locked in position. 2 Imaging Unit Motor rotation when the Start key is pressed: Cyan: the voltage across PJ12I-3B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Magenta: the voltage across PJ12I-7A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Yellow: the voltage across PJ12I-3A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Black: the voltage across PJ12I-7B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board.
Description: Imaging Unit Motor M turning at abnormal timing
The Lock signal remains faulty for a continuous 1sec. period after the motor has completely stopped and before the motor starts accelerating.
Remedy: 1 Imaging Unit Motor rotation while it is being energized: Cyan: the voltage across PJ12I-3B on Master Board and GND remains DC 0 V. Magenta: the voltage across PJ12I-7A on Master Board and GND remains DC 0 V. Yellow: the voltage across PJ12I-3A on Master Board and GND remains DC 0 V. Black: the voltage across PJ12I-7B on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.
Description: Imaging Unit Motor Y’s failure to turn
The Lock signal remains faulty for a continuous 1sec. period after the motor rotation has stabilized and before the motor starts decelerating.
Remedy: 1 Imaging Unit Motor turns when the Start key is pressed. NO: Correct drive coupling (drive transmitting gear engagement, coupling engagement). Check that the LED Assy is locked in position. 2 Imaging Unit Motor rotation when the Start key is pressed: Cyan: the voltage across PJ12I-3B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Magenta: the voltage across PJ12I-7A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Yellow: the voltage across PJ12I-3A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Black: the voltage across PJ12I-7B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board.
Description: Imaging Unit Motor Y turning at abnormal timing
The Lock signal remains faulty for a continuous 1sec. period after the motor has completely stopped and before the motor starts accelerating.
Remedy: 1 Imaging Unit Motor rotation while it is being energized: Cyan: the voltage across PJ12I-3B on Master Board and GND remains DC 0 V. Magenta: the voltage across PJ12I-7A on Master Board and GND remains DC 0 V. Yellow: the voltage across PJ12I-3A on Master Board and GND remains DC 0 V. Black: the voltage across PJ12I-7B on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.