Mã lỗi C0204 — Kyocera KMC1530

Code: C0204

Description: Yellow PC Drum Charge Corona malfunction
The SCD signal remains inactive for a continuous 1sec. period while charge corona is being output (i.e., the Remote signal is being turned ON).
Remedy: 1 Imaging Unit contact failure YES: Correct or clean Imaging Unit contact. 2 High Voltage Unit 1 contact failure YES: Correct or clean High Voltage Unit 1 contact. 3 After corona output has been turned ON: Cyan (C0200): The voltage across PJ9I-10 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Magenta (C0202): The voltage across PJ9I-8 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Yellow (C0204): The voltage across PJ9I-6 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Bk (C0206): The voltage across PJ9I-12 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. YES: Change High Voltage Unit 1. NO: Change Master Board.oard.