Code: C0410
Description: Exposure Lamp turning ON at abnormal timing
CCD Sensoroutputsare writteninlineRAM at the end of a scan job and the average of these readings exceeds a predetermined value.
CCD Sensoroutputsare writteninlineRAM at the end of a scan job and the average of these readings exceeds a predetermined value.
Remedy: 1 Exposure Lamp conduction NO: Change Exposure Lamp. 2 Temperature Fuse conduction. NO: Change Temperature Fuse. 3 Flat Cable conduction NO: Check for correct installation or change. 4 The problem has been eliminated through the checks of steps up to 3. NO: Change DC Power Supply 2. 5 Exposure Lamp turns ON and OFF correctly after DC Power Supply 2 has been replaced. NO: Change Image Processing Board.