Code: C0510
Description: Heating Roller abnormally low temperature (Fusing Thermistor 1)
• The temperature of Fusing Thermistor 1 remains below 120 C for 1 sec. or more in the standby state. • The temperature of Fusing Thermistor 1 remains below 130 C for 1 sec. or more during a print cycle. • The temperature of Fusing Thermistor 1 remains below 90 C for 1 sec. or more in the Energy Saver mode.
• The temperature of Fusing Thermistor 1 remains below 120 C for 1 sec. or more in the standby state. • The temperature of Fusing Thermistor 1 remains below 130 C for 1 sec. or more during a print cycle. • The temperature of Fusing Thermistor 1 remains below 90 C for 1 sec. or more in the Energy Saver mode.
Remedy: 1 Fusing Unit condition: the resistance across CN4-15 and 16 on the Fusing Unit end is infinity with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board. 2 Heating Roller Heater Lamps turn ON. YES: Change DC Power Supply 1. Change Master Board. NO: Change Fusing Unit.