Code: C3200
Description: Exposure lamp problem • Check the CCD input value for the lighting status of the exposure lamp 500 ms after the exposure lamp is lit and the carriage is moved to the shading position. If the exposure lamp does not light, a further 100 ms later, check the CCD input. The exposure lamp does not light after 50 retries.
Causes: Defective scanner main PCB. Defective exposure lamp or inverter PCB. Incorrect shading position. Poor contact of the connector terminals. Defective scanner sub PCB or CCD PCB.
Remedy: Replace the scanner main PCB and check for correct operation. Replace the exposure lamp or inverter PCB. Adjust the position of the contact glass (shading plate). If the problem still occurs, replace the scanner home position switch. Check the connection of connector YC1119 on the scanner main PCB, and the continuity across the connector terminals. Repair or replace if necessary. Replace the scanner sub PCB or CCD PCB and check for correct operation.