Code: 3100
Description: ISU home position error ON/OFF of the HP sensor doesn't change after a prescribed pulse passes from power supply ON.
Causes: Defective connector cable or poor contact in the connector. Defective home position sensor. Defective ISU motor. Defective CCD PWB. Defective PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Home position sensor and ISC PWB (YC8) ISC PWB and main PWB (YC11)
Defective home position sensor. Replace the home position sensor.
Defective ISU motor. Replace the ISU motor.
Defective CCD PWB. Replace the image scanner unit.
Defective PWB. Replace the main PWB and check for correct operation.
Defective home position sensor. Replace the home position sensor.
Defective ISU motor. Replace the ISU motor.
Defective CCD PWB. Replace the image scanner unit.
Defective PWB. Replace the main PWB and check for correct operation.