Description: 2nd transfer (paper transfer) disconnection (+) Paper transfer starts. - The positive (+) output is at the maximum PWM duty value for 60 milliseconds.
Causes: • Right cover not closed • Defective transfer roller contact mechanism • Defective high voltage supply board • Defective harness (BCU - high voltage supply board)