Mã lỗi 17 — Konica-Minolta Magicolor 2550EN

Code: 17

Description: Rack rotation failure
• The rack positioning sensor is in the blocked state when the rack motor remains deenergized.
• The rack positioning sensor is not blocked a second time even after the lapse of a predetermined period of time after it has been blocked once while the rack motor remains energized.
• The rack positioning sensor is unable to detect the deceleration control position after the lapse of a given period of time after the rack motor has started while the rack motor is turning.
• The count value of the edge of ON signal of the rack positioning sensor during each developing positions are not a predetermined value while the rack motor is turning.
Remedy: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check M2 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 PS3 sensor check. 5 M2 operation check. 6 Change PRCB.he