Các lỗi thường gặp

Code :
  • Code: 04
  • Description: Printer control board malfunction
    • Communications with the M/C expansion IO G/A (IC on the printer control board) are not properly carried out.
  • Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. 2 Change PRCB.
  • Code: 05
  • Description: Flash ROM malfunction
    • Firmware upgrading has failed.
  • Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. 2 Change PRCB.RCB.
  • Code: 08
  • Description: Main motor malfunction
    • The motor lock signal remains HIGH for a predetermined consecutive period of time while the main motor remains energized.
    • The motor lock signal remains LOW for a predetermined consecutive period of time while the main motor remains deenergized.
  • Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M1 operation check. 5 Change PRCB. 6 Change DCPU.
  • Code: 0B
  • Description: Ventilation fan motor malfunction
    • The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the ventilation fan motor remains energized.
  • Remedy: 1 Check the FM2 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 FM2 operation check. 5 Change PRCB. 6 Change DCPU.
  • Code: 0C
  • Description: Power supply cooling fan motor malfunction
    • The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the power supply cooling fan motor remains energized.
  • Remedy: 1 Check the FM1 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 FM1 operation check. 5 Change PRCB. 6 Change DCPU.
  • Code: 0F
  • Description: Cooling fan motor malfunction Duplex Option
  • Remedy:
  • Code: 10
  • Description: Polygon motor malfunction
    • A LOW motor lock signal is not detected even after the lapse of a predetermined period of time after the polygon motor has been started.
    • The motor lock signal remains HIGH for a predetermined consecutive period of time while the polygon motor remains energized.
  • Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change PRCB.
  • Code: 12
  • Description: Laser malfunction
    • The SOS signal is not detected within a predetermined period of time after the output of a laser has been started.
    • The SOS signal is never detected in the image area.
  • Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change PRCB.