Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 0096 — Konica-Minolta Magicolor 4750DN

Code: 0096

Display: XFER DETACH 1
Description: 1st image transfer pressure / retraction failure
• The 1st transfer release sensor is not activated (retracted position) within a given period of time after the 1st transfer release solenoid has turned ON. • The 1st transfer release sensor is not deactivated (pressed position) within a given period of time after the 1st transfer release solenoid has turned ON.
Remedy: 1 Check the connector between M2-PRCB PJ11 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 Check the connector between PS17-PRCB PJ26 for proper connection and correct as necessary. 4 Check the connector between SD1-relay CN25-PRCB PJ13 for proper connection and correct as necessary. 5 PS17 sensor check PRCB PJ26-3 (ON) I-15. 6 SD1 operation check PRCB PJ13-2 (REM) D-15. 7 M2 operation check PRCB PJ11-10 to 13 C-15. 8 Change PS17. 9 Change SD1. 10 Change M2. 11 Change PRCB.

← Xem tất cả mã lỗi Konica-Minolta Magicolor 4750DN

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie