Code: 0096
Display: XFER DETACH 1
Description: 1st image transfer pressure / retraction failure
• The 1st transfer release sensor is not activated (retracted position) within a given period of time after the 1st transfer release solenoid has turned ON. • The 1st transfer release sensor is not deactivated (pressed position) within a given period of time after the 1st transfer release solenoid has turned ON.
• The 1st transfer release sensor is not activated (retracted position) within a given period of time after the 1st transfer release solenoid has turned ON. • The 1st transfer release sensor is not deactivated (pressed position) within a given period of time after the 1st transfer release solenoid has turned ON.
Remedy: 1 Check the connector between M2-PRCB PJ11 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 Check the connector between PS17-PRCB PJ26 for proper connection and correct as necessary. 4 Check the connector between SD1-relay CN25-PRCB PJ13 for proper connection and correct as necessary. 5 PS17 sensor check PRCB PJ26-3 (ON) I-15. 6 SD1 operation check PRCB PJ13-2 (REM) D-15. 7 M2 operation check PRCB PJ11-10 to 13 C-15. 8 Change PS17. 9 Change SD1. 10 Change M2. 11 Change PRCB.