Description: Controller start up error • After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup. • After startup reset of the operation panel, the attention code (FDH) or the attention acknowledge code (FEH) was not sent from the controller within 30 sec.. • After the controller issued a command to check the ommunication line with the controller at 30-second intervals, the controller failed to respond twice.
Causes: • Controller stalled • Controller board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • The controller did not completely shut down when the switch was turned off.