Description: A lock signal of the main motor cannot be detected.
Causes:
Remedy: 1 Flat cable connection failure of main motor Check the flat cable connection of the main motor and reconnect them. 2 Main motor failure Replace the main motor. 3 Low voltage power supply PCB failure Replace the low voltage power supply PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.
Causes: • Clean the corona wire of drum unit. • Turn OFF the power switch, and turn it ON again after a while.
Remedy: 1 Dirt on the electrode of the drum unit and on the machine Clean the dirt on the contact points of the both electrodes. (Refer to Fig. 2-11, Fig. 2-12) 2 High voltage power supply PCB failure Replace the high voltage power supply PCB ASSY. 3 Main PCB failure Replace the main PCB ASSY.