Các lỗi thường gặp

Code :
  • Code: 6D
  • Description: Fuser unit error. (The center thermistor detects 60°C or lower temperature for 1 second during standby or printing.)
  • Causes:
  • Remedy: 1 Fuser unit connector connection failure Check the connector connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 Low voltage power supply PCB failure Replace the low voltage power supply PCB ASSY. 4 Paper eject sensor PCB failure Replace the paper eject sensor PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.
  • Code: 6F
  • Description: Fuser unit error. (The center and side thermistors detect extremely high temperature.) (Detection of hardware)
  • Causes:
  • Remedy: 1 Fuser unit connector connection failure Check the connector connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 Low voltage power supply PCB failure Replace the low voltage power supply PCB ASSY. 4 Paper eject sensor PCB failure Replace the paper eject sensor PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.
  • Code: 71
  • Description: Laser unit error.
  • Causes:
  • Remedy: 1 Correction value error of laser unit Input the correction value of the laser unit correctly. 2 Harness connection failure of laser unit Check the harness connection of the laser unit and reconnect them. 3 Main PCB failure Replace the main PCB ASSY. 4 Laser unit failure Replace the laser unit.
  • Code: 72
  • Description: Beam detecting sensor error of the laser unit.
  • Causes:
  • Remedy: 1 Correction value error of laser unit Input the correction value of the laser unit correctly. 2 Harness connection failure of laser unit Check the harness connection of the laser unit and reconnect them. 3 Main PCB failure Replace the main PCB ASSY. 4 Laser unit failure Replace the laser unit.
  • Code: 74
  • Description: An unidentified error occurred.
  • Causes: 1 Main PCB failure
  • Remedy: Replace the main PCB ASSY.
  • Code: 75
  • Description: Cooling down the inside of the machine to protect it.
  • Causes: • Leave the machine for a while as the power remains ON.
  • Remedy: 1 Internal temperature sensor failure Replace the internal temperature sensor. 2 Main PCB failure Replace the main PCB ASSY.
  • Code: 76
  • Description: Fuser unit error. (The center thermistor detects the sharp temperature rise.)
  • Causes:
  • Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Low voltage power supply PCB failure Replace the low voltage power supply PCB ASSY. 3 Paper eject sensor PCB failure Replace the paper eject sensor PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.
  • Code: 78
  • Description: Fuser unit error. (The center thermistor detects the sharp temperature fall.)
  • Causes:
  • Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Low voltage power supply PCB failure Replace the low voltage power supply PCB ASSY. 3 Paper eject sensor PCB failure Replace the paper eject sensor PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.