Code :
  • Code: B8
  • Description: A/D converter standard voltage failure; at Low side.
  • Causes:
  • Remedy: 1 White level data failure Execute the "Acquisition of white level data (Function code 55)". 2 Document scanner unit failure Replace the document scanner unit. 3 Main PCB failure Replace the main PCB ASSY.
  • Code: B9
  • Description: Scanning light adjustment error.
  • Causes:
  • Remedy: 1 White level data failure Execute the "Acquisition of white level data (Function code 55)". 2 Document scanner unit failure Replace the document scanner unit. 3 Main PCB failure Replace the main PCB ASSY.
  • Code: BB
  • Description: White level data error.
  • Causes:
  • Remedy: 1 White level data failure Execute the "Acquisition of white level data (Function code 55)". 2 Document scanner unit failure Replace the document scanner unit. 3 Main PCB failure Replace the main PCB ASSY.
  • Code: BD
  • Description: Black level data error.
  • Causes: Main PCB failure
  • Remedy: Replace the main PCB ASSY.
  • Code: C0
  • Description: Failure to detect a new toner cartridge.
  • Causes: 1 Power off or front cover opened while detecting a new toner cartridge.
  • Remedy: Reset the developing bias voltage and developer roller counter. (Refer to "2.1 Developer Roller Counter Reset Function" in Chapter 5.)
  • Code: C7
  • Description: Insufficient memory.
  • Causes: 1 Main PCB failure
  • Remedy: Replace the main PCB ASSY.
  • Code: C8
  • Description: RAM area for secure data full.
  • Causes: 1 Main PCB failure
  • Remedy: Replace the main PCB ASSY.
  • Code: D1
  • Description: Modem initialization failed.
  • Causes: 1 Main PCB failure
  • Remedy: Replace the main PCB ASSY.