Code: AF

Description: FB unit home position sensor is not turned off.
Causes: 1 Scanner unit failure. 2 Drive PCB failure. 3 Scanner motor failure. 4 Main PCB failure.
Remedy: 1 Scanner unit failure Replace the FB unit. 2 Drive PCB failure Replace the drive PCB. 3 Scanner motor failure Replace the scanner motor. 4 Main PCB failure Replace the main PCB ASSY.

Code: B0

Description: Harness for scanning is not connected correctly.
Causes: 1 Scanner harness not connected correctly. 2 Scanner harness broken. 3 Main PCB failure.
Remedy: 1 Scanner harness not connected correctly. Reconnect the scanner harness correctly. 2 Scanner harness broken Replace the FB unit. Replace the FFC cable ASSY. 3 Main PCB failure Replace the main PCB ASSY.

Code: B2

Description: Gain control data level error for CCD unit scanning.
Causes:
Remedy:

Code: B3

Description: Detection error of the scanning area on the left end
Causes: 1 Scanner unit failure. 2 Main PCB failure
Remedy: 1 Scanner unit failure Replace the FB unit. 2 Main PCB failure Replace the main PCB ASSY.

Code: B4

Description: Detection error of the scanning area on the right end
Causes: 1 Scanner unit failure. 2 Main PCB failure
Remedy: 1 Scanner unit failure Replace the FB unit. 2 Main PCB failure Replace the main PCB ASSY.

Code: B5

Description: Detection error of horizontal scanning edge reduction in scanning area setting
Causes: 1 White tape dirty of FB unit. 2 Scanner unit failure. 3 Main PCB failure.
Remedy: 1 White tape dirty of FB unit Clean the white tape. 2 Scanner unit failure Replace the FB unit. 3 Main PCB failure Replace the main PCB ASSY

Code: B6

Description: Detection error of horizontal scanning edge magnification in scanning area setting
Causes: 1 White tape dirty of FB unit. 2 Scanner unit failure. 3 Main PCB failure.
Remedy: 1 White tape dirty of FB unit Clean the white tape. 2 Scanner unit failure Replace the FB unit. 3 Main PCB failure Replace the main PCB ASSY

Code: B9

Description: Scanning light adjustment error is detected.
Causes: 1 Scanner unit failure. 2 Main PCB failure.
Remedy: 1 Scanner unit failure Replace the FB unit. 2 Main PCB failure Replace the main PCB ASSY.