Code :
- Code: 6A
- Description: Fuser temperature does not reach 60°C within the specified time (center thermistor)
- Causes: 1 Fuser unit failure. 2 Main PCB failure.
- Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Main PCB failure Replace the main PCB ASSY.
- Code: 6B
- Description: Fuser temperature does not reach 100°C within the specified time (center thermistor)
- Causes: 1 Fuser unit failure. 2 Main PCB failure.
- Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Main PCB failure Replace the main PCB ASSY.
- Code: 6C
- Description: Fuser temperature exceeds its higher limit (center thermistor)
- Causes: 1 Fuser unit failure. 2 Main PCB failure.
- Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Main PCB failure Replace the main PCB ASSY.
- Code: 6D
- Description: Fuser temperature exceeds its lower limit (center thermistor)
- Causes: 1 Fuser unit failure. 2 Main PCB failure.
- Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Main PCB failure Replace the main PCB ASSY.
- Code: 6E
- Description: Fuser temperature does not rise (center thermistor)
- Causes: 1 Fuser unit failure. 2 Main PCB failure.
- Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Main PCB failure Replace the main PCB ASSY.
- Code: 6F
- Description: Hardware detects extremely high temperature of the center or side thermistors
- Causes: 1 Fuser unit failure. 2 Main PCB failure.
- Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Main PCB failure Replace the main PCB ASSY.
- Code: 70
- Description: Fuser motor error
- Causes: 1 Motor failure. 2 Main PCB failure.
- Remedy: 1 Motor failure Replace the main motor. 2 Main PCB failure Replace the main PCB ASSY.
- Code: 71
- Description: Laser unit polygon motor failure
- Causes: 1 Laser unit failure. 2 Main PCB failure.
- Remedy: 1 Laser unit failure Replace the laser unit. 2 Main PCB failure Replace the main PCB ASSY.