Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Brother MFC8890DW — Trang 5/12

Code: 72

Description: Laser beam emission failure
Causes: 1 Laser unit failure. 2 Main PCB failure.
Remedy: 1 Laser unit failure Replace the laser unit. 2 Main PCB failure Replace the main PCB ASSY.

Code: 75

Description: Sensor of the inside temperature for detection detected higher than normal temperature
Causes: 1 Thermistor ASSY failure. 2 Main PCB failure.
Remedy: 1 Thermistor ASSY failure Replace the laser scanner unit. 2 Main PCB failure Replace the main PCB ASSY.

Code: 76

Description: Rapid temperature rising failure (center thermistor)
Causes: 1 Fuser unit failure. 2 Main PCB failure.
Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Main PCB failure Replace the main PCB ASSY.

Code: 78

Description: Rapid temperature falling failure (center thermistor)
Causes: 1 Fuser unit failure. 2 Main PCB failure.
Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Main PCB failure Replace the main PCB ASSY.

Code: 7A

Description: No detection of main motor synchronous signal
Causes: 1 Motor failure. 2 Main PCB failure.
Remedy: 1 Motor failure Replace the main motor. 2 Main PCB failure Replace the main PCB ASSY.

Code: 7D

Description: Dirt on corona wire (detect discharge error)
Causes: 1 Dirt or dust on drum unit electrodes. 2 Charge HVPS PCB failure. 3 Main PCB failure
Remedy: 1 Dirt or dust on drum unit electrodes Clean the electrodes of the main body and the drum unit. 2 Charge HVPS PCB failure Replace the charge HVPS PCB ASSY. 3 Main PCB failure Replace the main PCB ASSY.

Code: 7F

Description: Fax paper setting mismatch (The setting paper becomes besides the A4/Letter/Legal/ Folio) (Not applicable)
Causes: 1 Registration front actuator 2 catching on some position. 2 Main PCB failure
Remedy: 1 Registration front actuator 2 catching on some position Correct catching of the registration front actuator 2. 2 Main PCB failure Replace the main PCB ASSY.

Code: 80

Description: Fax paper size is incorrect (The paper is smaller 10mm than the letter size (11inch) in Fax List/ Report)
Causes: 1 Registration front actuator 2 catching on some position. 2 Main PCB failure
Remedy: 1 Registration front actuator 2 catching on some position Correct catching of the registration front actuator 2. 2 Main PCB failure Replace the main PCB ASSY.