Description: Error in Developing Disengagement Motor
Causes: Change in signal status of the Developing Home Position Sensor could not be detected although a specified period of time has passed after rotating the Main Motor for engagement/ disengagement operation of the Developing Cylinder.
Remedy: 1. Check the connectors connecting the Developing Home Position Sensor, Main Motor and the DC Controller PCB. 2. Replace the Developing Home Position Sensor. 3. Replace the Main Motor. 4. Replace the DC Controller PCB.
Code: E020 0000
Description: Density Sensor error
Causes: Sufficient amount of light could not be received when detecting image density.
Remedy: 1. Check the connector of the DC Controller PCB. 2. Replace the ITB Unit. 3. Replace the DC Controller PCB. 4. Replace the Toner Cartridge.
Code: E066 0000
Description: Environment Sensor error
Causes: Environment Sensor error
Remedy: 1. Check the connector between the Environment Sensor and DC Controller PCB. 2. Replace the Environment Sensor. 3. Replace the DC Controller PCB.
Code: E070 0000
Description: ITB/TOP Sensor error
Causes: ITB/TOP Sensor error
Remedy: 1. Check the connector between the ITB Unit and DC Controller PCB. 2. Replace the ITB Unit. 3. Replace the DC Controller PCB.
Code: E100 0000
Description: Error in Laser Scanner Motor or Laser Scanner Unit (Y)
Causes: Error in the BD detection value in the Laser Scanner Motor or the Laser Scanner Unit (Y)
Remedy: 1. Check the connector between the Laser Scanner Unit and the DC Controller PCB. 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB.
Code: E100 0001
Description: Error in Laser Scanner Motor or Laser Scanner Unit (Y)
Causes: Error in the BD detection value in the Laser Scanner Motor or the Laser Scanner Unit (Y)
Remedy: 1. Check the connector between the Laser Scanner Unit and the DC Controller PCB. 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB.
Code: E100 0002
Description: Error in Laser Scanner Motor or Laser Scanner Unit (C)
Causes: Error in the BD detection value in the Laser Scanner Motor or the Laser Scanner Unit (C)
Remedy: 1. Check the connector between the Laser Scanner Unit and the DC Controller PCB. 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB.
Code: E100 0003
Description: Error in Laser Scanner Motor or Laser Scanner Unit (Bk)
Causes: Error in the BD detection value in the Laser Scanner Motor or the Laser Scanner Unit (Bk)
Remedy: 1. Check the connector between the Laser Scanner Unit and the DC Controller PCB. 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB.