Description: Error in access to backup data for Reader (reading error at power-on)
Causes: The Reader-related adjustment values could not be read.
Remedy: 1. Clear the backup RAM of RCON. Execute COPIER > FUNCTION > CLEAR > RCON. 2. Enter all the values written on the service label in service mode again. 3. Turn OFF and then ON the main power.
Remedy: 1. Check the connector connection between the Engine Controller PCB and the Main Controller PCB. 2. Install the set of the controller firmware. 3. Replace the Main Controller PCB. 4. Replace the Engine Controller PCB.
Causes: Communication error between the Engine Controller PCB and the Main Controller PCB occurred.
Remedy: 1. Check the connector connection between the Engine Controller PCB and the Main Controller PCB. 2. Install the set of the controller firmware. 3. Replace the Main Controller PCB. 4. Replace the Engine Controller PCB.