Description: Error in Developing Disengagement Motor
Causes: Change in signal status of the Developing Home Position Sensor could not be detected although a specified period of time has passed after rotating the Main Motor for engagement/ disengagement operation of the Developing Cylinder.
Remedy: 1. Check the connectors connecting the Developing Home Position Sensor, Main Motor and the DC Controller PCB. 2. Replace the Developing Home Position Sensor. 3. Replace the Main Motor. 4. Replace the DC Controller PCB.
Remedy: 1. Check the connector between the Developing Motor and the DC Controller PCB. 2. Replace the Developing Motor. 3. Replace the DC Controller PCB.
Causes: The cycle of the Developing Motor speed detection signal did not become the specified cycle since the Developing Motor started to be driven.
Remedy: 1. Check the connector between the Developing Motor and the DC Controller PCB. 2. Replace the Developing Motor. 3. Replace the DC Controller PCB.