Description: Light intensity of the CIS Unit below the reference level
Causes: When the light intensity is below the reference level at shading
Remedy: 1. Disconnect and then connect the Flexible Cable. 2. Replace the Flexible Cable. 3. Replace the CIS Unit. 4. Replace the Main Controller PCB (PCB2).
Code: E246 0000
Description: System error
Causes: System error
Remedy: Contact to the sales company's HQ.
Code: E247 0000
Description: System error
Causes: System error
Remedy: Contact to the sales company's HQ.
Code: E248 0001
Description: Error in access to backup data for Reader (reading error at power-on)
Causes: The Reader-related adjustment values could not be read.
Remedy: 1. Clear the backup RAM of RCON. Execute COPIER > FUNCTION > CLEAR > RCON. 2. Enter all the values written on the service label in service mode again. 3. Turn OFF and then ON the main power.
Code: E250 0000
Description: Error in the One-Touch Key Cover Sensor
Causes: Error in the One-Touch Key Cover Sensor
Remedy: 1. Check the One-Touch Key Cover Sensor. 2. Turn OFF and then ON the power. 3. Replace the Control Panel.