Causes: Top Sensor/ Media Width Sensor/ Fixing Delivery Sensor/ Duplex Reverse Sensor PS204/PS205/ PS915/ PS201
Remedy:
Code: 11D8
Description: Door Open Jam 1
Causes: Top Sensor/ Media Width Sensor/ Fixing Delivery Sensor/ Duplex Reverse Sensor PS204/PS205/ PS915/ PS201
Remedy:
Code: E000-0000
Description: Error in temperature rising of Fixing Assembly
Causes: Temperature of the Fixing Assembly did not reach a certain temperature within the specified period of time.
Remedy: 1. Check the connector connection between the Fixing Assembly and the Engine Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the Engine Controller PCB.
Code: E001-0000
Description: Abnormal high temperature of Fixing Assembly
Causes: It was detected that the temperature of the Fixing Assembly was abnormally high.
Remedy: 1. Check the connector connection between the Fixing Assembly and the Engine Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the Engine Controller PCB.
Code: E003-0000
Description: Abnormal low temperature of Fixing Assembly
Causes: It was detected that the temperature of the Fixing Assembly was abnormally low.
Remedy: 1. Check the connector connection between the Fixing Assembly and the Engine Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the Engine Controller PCB.
Code: E004-0000
Description: Error in fixing power supply drive circuit
Causes: The zero cross signal was not detected for the specified period of time or more.
Remedy: 1. Check the connector connection between the Fixing Assembly and the Engine Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the Engine Controller PCB.
Code: E014-0000
Description: Error in startup of the Main Motor
Causes: Revolution of the Main Motor did not reach the specified value.
Remedy: 1. Check the connector connection between the Main Motor and the Engine Controller PCB. 2. Replace the Main Motor. 3. Replace the Engine Controller PCB.
Code: E100-0000
Description: Laser Scanner Assembly error
Causes: BD cycle of the Laser Scanner Unit was not within the specified range.
Remedy: 1. Check the connector connection between the Main Controller PCB and the Laser Scanner Unit. 2. Check the connector connection between the Relay PCB and the Laser Scanner Unit. 3. Replace the Laser Scanner Unit.