Các lỗi thường gặp

Code :
  • Code: E805-0002
  • Description: Fan 2 failure
  • Causes: Fan 2 failure
  • Remedy: 1. Check the connection of the Fan 2 2. Replace the Fan 2. 3. Replace the DC Controller PCB.
  • Code: E808-0001
  • Description: Low-voltage power supply failure
  • Causes: Low-voltage power supply failure was detected.
  • Remedy: 1. Check the connection of the Power Supply PCB or the connector. 2. Replace the Power Supply PCB.
  • Code: E840-0000
  • Description: Fixing disengagement error
  • Causes: Fixing pressure release mechanism error
  • Remedy: 1. Check the connector between the Fixing Assembly and the Power Supply PCB. 2. Replace the Fixing Assembly. 3. Replace the Power Supply PCB.
  • Code: F9-nn-Error
  • Description: System error
  • Causes: Communication error between the Main Controller and the Control Panel
  • Remedy: • Check for any poor contact/open circuit of the connector between the Main Controller and the Control Panel. If there is no problem with the connector but the error persists, obtain the following information and contact the department in charge of quality management. • Output STATUS PRINT/PPRINT. • Collect Sublog • Collect information on conditions to reproduce the error