Causes: Fixing motor speed detection signal frequency does not reach specified frequency within 2.5 sec. or longer of the fixing motor drive starting. Cause: Fixing motor defect, DC controller PCB defect
Remedy: - Replace fixing motor - Replace DC controller PCB
Code: E014-0001
Description: Fixing motor drive abnormality
Causes: Fixing motor speed detection signal frequency reaches the specified frequency but is then out of synch after 2 sec. or longer of operation. Cause: Fixing motor defect, DC controller PCB defect
Remedy: - Replace fixing motor - Replace DC controller PCB
Code: E020
Description: Density sensor abnormality
Causes: Not enough light received upon image density detection. Cause: Soiled density detection sensor, density detection sensor defect, DC controller PCB defect, toner cartridge defect
Remedy: - Replace ETB unit - High voltage contact defect (check contacts from high voltage contacts of each colour station to high voltage PCB.) - Replace DC controller PCB - Replace toner cartridge