Các lỗi thường gặp

Code :
  • Code: E012-0002
  • Description: Motor startup abnormality
  • Causes: Drum motor speed detection signal frequency does not reach specified frequency within 2.5 sec. or longer of the yellow motor drive starting. Cause:Drum motor defect, DC controller PCB defect
  • Remedy: - Replace drum motor - Replace DC controller PCB
  • Code: E012-0003
  • Description: Motor startup abnormality
  • Causes: Yellow motor speed detection signal frequency reaches the specified frequency but is then out of synch after 2 sec. or longer of operation. Cause: Drum motor defect, DC controller PCB defect
  • Remedy: - Replace drum motor - Replace DC controller PCB
  • Code: E012-0004
  • Description: Motor startup abnormality
  • Causes: Drum motor speed detection signal frequency does not reach specified frequency within 2.5 sec. or longer of the magenta motor drive starting. Cause: Drum motor defect, DC controller PCB defect
  • Remedy: - Replace drum motor - Replace DC controller PCB
  • Code: E012-0005
  • Description: Motor startup abnormality
  • Causes: Magenta motor speed detection signal frequency reaches the specified frequency but is then out of synch after 2 sec. or longer of operation. Cause: Drum motor defect, DC controller PCB defect
  • Remedy: - Replace drum motor - Replace DC controller PCB
  • Code: E012-0006
  • Description: Motor startup abnormality
  • Causes: Drum motor speed detection signal frequency does not reach specified frequency within 2.5 sec. or longer of the cyan motor drive starting. Cause: Drum motor defect, DC controller PCB defect
  • Remedy: - Replace drum motor - Replace DC controller PCB
  • Code: E012-0007
  • Description: Motor startup abnormality
  • Causes: Cyan motor speed detection signal frequency reaches the specified frequency but is then out of synch after 2 sec. or longer of operation. Cause: Drum motor defect, DC controller PCB defect
  • Remedy: - Replace drum motor - Replace DC controller PCB
  • Code: E012-0008
  • Description: Motor startup abnormality
  • Causes: Drum motor speed detection signal frequency does not reach specified frequency within 2.5 sec. or longer of the black motor drive starting. Cause: Drum motor defect, DC controller PCB defect
  • Remedy: - Replace drum motor - Replace DC controller PCB
  • Code: E012-0009
  • Description: Motor startup abnormality
  • Causes: Black motor speed detection signal frequency reaches the specified frequency but is then out of synch after 2 sec. or longer of operation. Cause: Drum motor defect, DC controller PCB defect
  • Remedy: - Replace drum motor - Replace DC controller PCB