Remedy: 1. Check the connection of the Power Fan. 2. Replace the Power Fan. 3. Replace the DC Controller PCB.
Code: E808-0001
Description: Low-voltage power supply failure
Causes: Low-voltage power supply failure was detected.
Remedy: 1. Check the connection of the Low Voltage Power Supply Unit or the connector. 2. Check the connection of the AC Relay PCB or the connector. 3. Replace the Low Voltage Power Supply Unit. 4. Replace the AC Relay PCB.
Code: E825-0000
Description: Yellow Drum Home Position Sensor error warning
Causes: An error of the Drum Home Position Sensor is detected.
Remedy: 1. Check the connector of the Drum Home Position Sensor. 2. Replace the Drum Home Position Sensor. 3. Replace the DC Controller PCB.
Code: E825-0001
Description: Magenta Drum Home Position Sensor error warning
Causes: An error of the Drum Home Position Sensor is detected.
Remedy: 1. Check the connector of the Drum Home Position Sensor. 2. Replace the Drum Home Position Sensor. 3. Replace the DC Controller PCB.
Code: E825-0002
Description: Cyan Drum Home Position Sensor error warning
Causes: An error of the Drum Home Position Sensor is detected.
Remedy: 1. Check the connector of the Drum Home Position Sensor. 2. Replace the Drum Home Position Sensor. 3. Replace the DC Controller PCB.
Code: E825-0003
Description: Black Drum Home Position Sensor error warning
Causes: An error of the Drum Home Position Sensor is detected.
Remedy: 1. Check the connector of the Drum Home Position Sensor. 2. Replace the Drum Home Position Sensor. 3. Replace the DC Controller PCB.
Code: E840-0000
Description: Fixing disengagement error
Causes: Fixing pressure release mechanism error
Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.
Code: F9-nn-Error
Description: System error
Causes: Communication error between the Main Controller and the Control Panel
Remedy: - Check for any poor contact/open circuit of the connector between the Main Controller and the Control Panel. If there is no problem with the connector but the error persists, obtain the following information and contact the department in charge of quality management. - Output STATUS PRINT/PPRINT. - Collect Sublog - Collect information on conditions to reproduce the error