Các lỗi thường gặp

Code :
  • Code: E805-0020
  • Description: Power Fan failure
  • Causes: Power Fan failure
  • Remedy: 1. Check the connection of the Power Fan. 2. Replace the Power Fan. 3. Replace the DC Controller PCB.
  • Code: E808-0001
  • Description: Low-voltage power supply failure
  • Causes: Low-voltage power supply failure was detected.
  • Remedy: 1. Check the connection of the Low Voltage Power Supply Unit or the connector. 2. Check the connection of the AC Relay PCB or the connector. 3. Replace the Low Voltage Power Supply Unit. 4. Replace the AC Relay PCB.
  • Code: E825-0000
  • Description: Yellow Drum Home Position Sensor error warning
  • Causes: An error of the Drum Home Position Sensor is detected.
  • Remedy: 1. Check the connector of the Drum Home Position Sensor. 2. Replace the Drum Home Position Sensor. 3. Replace the DC Controller PCB.
  • Code: E825-0001
  • Description: Magenta Drum Home Position Sensor error warning
  • Causes: An error of the Drum Home Position Sensor is detected.
  • Remedy: 1. Check the connector of the Drum Home Position Sensor. 2. Replace the Drum Home Position Sensor. 3. Replace the DC Controller PCB.
  • Code: E825-0002
  • Description: Cyan Drum Home Position Sensor error warning
  • Causes: An error of the Drum Home Position Sensor is detected.
  • Remedy: 1. Check the connector of the Drum Home Position Sensor. 2. Replace the Drum Home Position Sensor. 3. Replace the DC Controller PCB.
  • Code: E825-0003
  • Description: Black Drum Home Position Sensor error warning
  • Causes: An error of the Drum Home Position Sensor is detected.
  • Remedy: 1. Check the connector of the Drum Home Position Sensor. 2. Replace the Drum Home Position Sensor. 3. Replace the DC Controller PCB.
  • Code: E840-0000
  • Description: Fixing disengagement error
  • Causes: Fixing pressure release mechanism error
  • Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.
  • Code: F9-nn-Error
  • Description: System error
  • Causes: Communication error between the Main Controller and the Control Panel
  • Remedy: - Check for any poor contact/open circuit of the connector between the Main Controller and the Control Panel. If there is no problem with the connector but the error persists, obtain the following information and contact the department in charge of quality management. - Output STATUS PRINT/PPRINT. - Collect Sublog - Collect information on conditions to reproduce the error