Các lỗi thường gặp

Code :
  • Code: E602-1102
  • Description: File system could not be initialized normally (MEAP-related).
  • Causes: File system could not be initialized normally (MEAP-related).
  • Remedy: 1. Turning OFF and then ON the main power executes auto recovery. Since E616-0001 may be displayed in some cases, execute the remedy for E616-0001. * When this error occurs, the firmware downloaded by the CDS Updater will be lost.
  • Code: E602-1112
  • Description: Device access error (MEAP-related)
  • Causes: Device access error (MEAP-related)
  • Remedy: 1. Turning OFF and then ON the main power executes auto recovery. Since E616-0001 may be displayed in some cases, execute the remedy for E616-0001. * When this error occurs, the firmware downloaded by the CDS Updater will be lost.
  • Code: E602-1113
  • Description: Device access error (MEAP-related)
  • Causes: Device access error (MEAP-related)
  • Remedy: 1. Turning OFF and then ON the main power executes auto recovery. Since E616-0001 may be displayed in some cases, execute the remedy for E616-0001. * When this error occurs, the firmware downloaded by the CDS Updater will be lost.
  • Code: E602-1302
  • Description: File system could not be initialized normally.
  • Causes: File system could not be initialized normally.
  • Remedy: 1. Turning OFF and then ON the main power executes auto recovery. * When this error occurs, the firmware downloaded by the CDS Updater will be lost.
  • Code: E602-1312
  • Description: Device access error
  • Causes: Device access error
  • Remedy: 1. Turning OFF and then ON the main power executes auto recovery. * When this error occurs, the firmware downloaded by the CDS Updater will be lost.
  • Code: E602-1313
  • Description: Device access error
  • Causes: Device access error
  • Remedy: 1. Turning OFF and then ON the main power executes auto recovery. * When this error occurs, the firmware downloaded by the CDS Updater will be lost.
  • Code: E602-1602
  • Description: File system could not be initialized normally (CDS-related).
  • Causes: File system could not be initialized normally (CDS-related).
  • Remedy: 1. Turning OFF and then ON the main power executes auto recovery. * When this error occurs, the firmware downloaded by the CDS Updater will be lost.
  • Code: E602-1612
  • Description: Device access error (CDS-related)
  • Causes: Device access error (CDS-related)
  • Remedy: 1. Turning OFF and then ON the main power executes auto recovery. * When this error occurs, the firmware downloaded by the CDS Updater will be lost.