Các lỗi thường gặp

Code :
  • Code: D7-nn-Error
  • Description: System error
  • Causes: System error
  • Remedy: - Turn OFF and then ON the main power. If the error persists, obtain the following information and contact the department in charge of quality management. - Output STATUS PRINT/ P-PRINT. - Collect Sublog - Collect information on conditions to reproduce the error - Obtain user's print data (binary data)
  • Code: D8-nn-Error
  • Description: System error
  • Causes: System error
  • Remedy: - Turn OFF and then ON the main power. If the error persists, obtain the following information and contact the department in charge of quality management. - Output STATUS PRINT/ P-PRINT. - Collect Sublog - Collect information on conditions to reproduce the error - Obtain user's print data (binary data)
  • Code: D9-nn-Error
  • Description: System error
  • Causes: System error
  • Remedy: - Turn OFF and then ON the main power. If the error persists, obtain the following information and contact the department in charge of quality management. - Output STATUS PRINT/ P-PRINT. - Collect Sublog - Collect information on conditions to reproduce the error - Obtain user's print data (binary data)
  • Code: E000-0000
  • Description: Fixing temperature rising error
  • Causes: Temperature of the Main Thermistor did not become the specified temperature although the specified time had passed.
  • Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit
  • Code: E001-0000
  • Description: Abnormally high fixing temperature 1
  • Causes: The Main Thermistor detected a temperature higher than the specified temperature.
  • Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.
  • Code: E001-0001
  • Description: Abnormally high fixing temperature 2
  • Causes: The Sub Thermistor 1 detected a temperature higher than the specified temperature.
  • Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.
  • Code: E001-0004
  • Description: Abnormally high fixing temperature 3
  • Causes: The Sub Thermistor 2 detected a temperature higher than the specified temperature.
  • Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.
  • Code: E003-0000
  • Description: Abnormally low fixing temperature detection 1
  • Causes: Temperature of the Main Thermistor was lower than the specified temperature when the heater was ON.
  • Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.