Causes: Error in ITB/TOP sensor Cause Failure in ITB/TOP sensor, failure in DC controller PCB
Remedy: - Check the connectors of the ITB unit and DC controller PCB - Replace the ITB - Replace the DC controller PCB
Code: E078
Description: Error in primary transfer disengagement.
Causes: Primary transfer disengagement system can not work properly. Cause Breakdown in disengagement system, failure in ITB tension sensor, failure in pickup motor, failure in DC controller PCB.
Remedy: - Check the disengagement system - Check the connectors of ITB tension sensor, pick up motor, and DC controller PCB - Replace the ITB tension sensor
Code: E100-0000
Description: Error in scanner motor, laser unit, and BD.
Causes: Breakdown in yellow scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
Remedy: - Check the connectors of the laser scanner unit and DC controller PCB - Replace the laser scanner unit - Replace the DC controller PCB
Code: E100-0001
Description: Error in scanner motor, laser unit, and BD.
Causes: Breakdown in magenta scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
Remedy: - Check the connectors of the laser scanner unit and DC controller PCB - Replace the laser scanner unit - Replace the DC controller PCB
Code: E100-0002
Description: Error in scanner motor, laser unit, and BD.
Causes: Breakdown in cyan scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
Remedy: - Check the connectors of the laser scanner unit and DC controller PCB - Replace the laser scanner unit - Replace the DC controller PCB
Code: E100-0003
Description: Error in scanner motor, laser unit, and BD.
Causes: Breakdown in black scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
Remedy: - Check the connectors of the laser scanner unit and DC controller PCB - Replace the laser scanner unit - Replace the DC controller PCB
Code: E110
Description: Error in first artificial BD adjustment
Causes: If scanner does not become "Ready" after the artifical BD control is started.
Remedy: - Replace the laser scanner unit - Replace the DC controller PCB
Code: E194
Description: Error in CPR sensor
Causes: If CPR sensor is judged error. Cause Soiling in density detection sensor, failure in density detection sensor, failure in DC controller PCB, failure in toner cartridge.
Remedy: - Check the connector of DC controller PCB - Replace the ITB unit - Replace the DC controller PCB - Replace the toner cartridge