Description: Error in DCON ROM. Failure in ROM update of DC controller PCB
Causes: Can not access to DC controller NVRAM Cause Failure in DC controller PCB
Remedy: - Replace the DC controller PCB
Code: E197-0001
Description: Engine communication error
Causes: Error between DC controller PCB and main controller PCB. Cause Failure in connection between PCB, failure in DC controller PCB, failure in controller PCB.
Remedy: - Check the connection of the connector of the DC controller PCB and controller PCB - Replace the DC controller PCB - Replace the controller PCB
Code: E198
Description: Breakdown in DC controller memory
Causes: Breakdown in DC controller memory Cause Failure in DC controller PCB
Remedy: - Replace the DC controller PCB
Code: E747
Description: EEPROM error
Causes: Failure in main controller PCB
Remedy: - Replace the main controller PCB
Code: E805-0005
Description: Error in duplex cooling fan
Causes: Duplex cooling fan can not rotate the specified number of rotations. Cause Failure in duplex cooling fan, failure in DC controller PCB
Remedy: - Check the connectors of duplex cooling fan and DC controller PCB - Replace the duplex cooling fan
Code: E806
Description: Error in power supply cooling fan
Causes: Power cooling fan can not rotate the specified number of rotations. Cause Failure in power supply cooling fan, failure in DC controller PCB
Remedy: - Check the connectors of power supply cooling fan and DC controller PCB - Replace the power cooling fan
Code: E808
Description: Error in low voltage power supply.
Causes: If printer detects a breakdown in low voltage power supply. Cause Breakdown in low pressure power supply, failure in DC controller PCB
Remedy: - Check the connectors of power unit and DC controller PCB - Replace the power unit
Code: E840
Description: Error in pressure release system.
Causes: Control home position (in pressured condition) cannot function after the home position control is started. Cause Failure in fixing drive assembly, failure in fixing pressure release cam.
Remedy: - Replace the fixing drive assembly - Replace the fixing pressure release cam