Causes: The Laser Scanner Motor did not become ready although a specified period of time had passed.
Remedy: 1. Replace the Laser Scanner Unit. 2. Replace the DC Controller PCB.
Code: E196 0000
Description: DCON ROM error
Causes: The ROM of the DC Controller PCB failed to be updated.
Remedy: 1. Install the set of the controller firmware. 2. Replace the DC Controller PCB.
Code: E196 1000
Description: Main Controller PCB writing/reading error
Causes: Error in writing/reading of main program in the Main Controller PCB
Remedy: 1. Install the set of the controller firmware. 2. Replace the Main Controller PCB.
Code: E196 2000
Description: Main Controller PCB writing/reading error
Causes: Error in writing/reading of the setting values storage area in the Main Controller PCB
Remedy: 1. Install the set of the controller firmware. 2. Replace the Main Controller PCB.
Code: E198 0000
Description: DC Controller memory error
Causes: Error in the nonvolatile memory on the DC Controller
Remedy: Replace the DC Controller PCB.
Code: E202 0001
Description: CIS Unit HP error (outward)
Causes: The CIS Unit did not move to HP even it moved backward. Reader HP Sensor error, Reader Motor error, CIS Unit error
Remedy: 1. Replace the Reader HP Sensor. 2. Replace the Reader Motor. 3. Replace the CIS Unit. 4. Replace the Reader Unit.
Code: E202 0002
Description: CIS Unit HP error (homeward)
Causes: The CIS Unit did not move to HP even it moved forward. Reader HP Sensor error, Reader Motor error, CIS Unit error
Remedy: 1. Replace the Reader HP Sensor. 2. Replace the Reader Motor. 3. Replace the CIS Unit. 4. Replace the Reader Unit.
Code: E225 0001
Description: Light intensity of the CIS Unit below the reference level
Causes: When the light intensity is below the reference level at shading
Remedy: 1. Disconnect and then connect the Flexible Cable. 2. Replace the Flexible Cable. 3. Replace the CIS Unit. 4. Replace the Main Controller PCB (PCB2).