Các lỗi thường gặp

Code :
  • Code: 04 0071
  • Description: Sequence Error
  • Causes:
  • Remedy:
  • Code: 04 0094
  • Description: Document End Sensor / Document Sensor
  • Causes: PS702/PS703
  • Remedy:
  • Code: E000 0000
  • Description: Error in temperature rising of Fixing Assembly
  • Causes: Temperature of the Fixing Assembly did not reach a certain temperature within the specified period of time.
  • Remedy: 1. Check the connector connection between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
  • Code: E001 0000
  • Description: Abnormal high temperature of Fixing Assembly
  • Causes: It was detected that the temperature of the Fixing Assembly was abnormally high.
  • Remedy: 1. Check the connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
  • Code: E003 0000
  • Description: Abnormal low temperature of Fixing Assembly
  • Causes: It was detected that the temperature of the Fixing Assembly was abnormally low.
  • Remedy: 1. Check the connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
  • Code: E004 0000
  • Description: Error in fixing power supply drive circuit
  • Causes: The zero cross signal was not detected for the specified period of time or more.
  • Remedy: 1. Check the connector connection between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
  • Code: E012 0000
  • Description: Revolution of the ITB Motor did not reach the specified value
  • Causes: The cycle of the ITB Motor speed detection signal did not become the specified cycle since the ITB Motor started to be driven.
  • Remedy: 1. Check the connector between the ITB Motor and the DC Controller PCB. 2. Replace the ITB Motor. 3. Replace the DC Controller PCB.
  • Code: E012 0001
  • Description: Revolution of the ITB Motor was out of the specified range
  • Causes: After the cycle of the ITB Motor speed detection signal became the specified cycle once, it deviated from the specified cycle.
  • Remedy: 1. Check the connector between the ITB Motor and the DC Controller PCB. 2. Replace the ITB Motor. 3. Replace the DC Controller PCB.
 < 1 2 3 4 5 6 7 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục