Các lỗi thường gặp

Code :
  • Code: E015 0001
  • Description: Error in Developing Disengagement Motor
  • Causes: Change in signal status of the Developing Home Position Sensor could not be detected although a specified period of time has passed after rotating the Main Motor for engagement/ disengagement operation of the Developing Cylinder.
  • Remedy: 1. Check the connectors connecting the Developing Home Position Sensor, Main Motor and the DC Controller PCB. 2. Replace the Developing Home Position Sensor. 3. Replace the Main Motor. 4. Replace the DC Controller PCB.
  • Code: E020 0000
  • Description: Density Sensor error
  • Causes: Sufficient amount of light could not be received when detecting image density.
  • Remedy: 1. Check the connector of the DC Controller PCB. 2. Replace the ITB Unit. 3. Replace the DC Controller PCB. 4. Replace the Toner Cartridge.
  • Code: E066 0000
  • Description: Environment Sensor error
  • Causes: Environment Sensor error
  • Remedy: 1. Check the connector between the Environment Sensor and DC Controller PCB. 2. Replace the Environment Sensor. 3. Replace the DC Controller PCB.
  • Code: E070 0000
  • Description: ITB/TOP Sensor error
  • Causes: ITB/TOP Sensor error
  • Remedy: 1. Check the connector between the ITB Unit and DC Controller PCB. 2. Replace the ITB Unit. 3. Replace the DC Controller PCB.
  • Code: E100 0000
  • Description: Error in Laser Scanner Motor or Laser Scanner Unit (Y)
  • Causes: Error in the BD detection value in the Laser Scanner Motor or the Laser Scanner Unit (Y)
  • Remedy: 1. Check the connector between the Laser Scanner Unit and the DC Controller PCB. 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB.
  • Code: E100 0001
  • Description: Error in Laser Scanner Motor or Laser Scanner Unit (Y)
  • Causes: Error in the BD detection value in the Laser Scanner Motor or the Laser Scanner Unit (Y)
  • Remedy: 1. Check the connector between the Laser Scanner Unit and the DC Controller PCB. 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB.
  • Code: E100 0002
  • Description: Error in Laser Scanner Motor or Laser Scanner Unit (C)
  • Causes: Error in the BD detection value in the Laser Scanner Motor or the Laser Scanner Unit (C)
  • Remedy: 1. Check the connector between the Laser Scanner Unit and the DC Controller PCB. 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB.
  • Code: E100 0003
  • Description: Error in Laser Scanner Motor or Laser Scanner Unit (Bk)
  • Causes: Error in the BD detection value in the Laser Scanner Motor or the Laser Scanner Unit (Bk)
  • Remedy: 1. Check the connector between the Laser Scanner Unit and the DC Controller PCB. 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB.