Description: Scanner power state error (firmware-dependent)
Causes: Error in power state of the Laser Scanner Unit (firmware-dependent)
Remedy: 1. Install the set of the controller firmware. 2. Replace the Laser Scanner Unit.
Code: E766 xxxx
Description: Firmware error
Causes: An error in connection occurred due to controller software.
Remedy: Due to firmware error, the possibility of solving the error by replacing the Main Controller PCB is low. Check the installed engine again.
Code: E806 0000
Description: Fixing Power Supply Cooling Fan error
Causes: The Fixing Power Supply Cooling Fan failed to rotate at the specified revolution.
Remedy: 1. Check the connector between the Fixing Power Supply Cooling Fan and the DC Controller PCB. 2. Replace the Fixing Power Supply Cooling Fan. 3. Replace the DC Controller PCB.
Code: E840 0000
Description: Error in pressure release mechanism of the Fixing Assembly
Causes: Although the Fixing Assembly started moving to the home position, it failed to be at the position.
Remedy: 1. Replace the Fixing Drive Assembly. 2. Replace the Fixing Pressure Release Cam.